Detail Specifications
Overall Height:
2.250 inches
Body Length:
Between 6.220 inches and 6.280 inches
Body Width:
Between 1.440 inches and 1.500 inches
Body Height:
Between 1.770 inches and 1.830 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 5.820 inches and 5.840 inches
Vibration Resistance Range In Hertz:
+10.0/+2000.0
Vibration Resistance Range In Hertz:
+10.0 to 2000.0
Operating Tempurature Range:
-55.0/+95.0 degrees celsius
Operating Tempurature Range:
-55.0 to 95.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
Operating Current Rating Per Function In Amps:
1.5 3rd radio interference
Operating Current Rating Per Function In Amps:
1.5 4th radio interference
Operating Current Rating Per Function In Amps:
2.5 1st radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.5 4th radio interference 4th function
Operating Current Rating Per Function In Amps:
2.5 1st radio interference 1st function
Maximum Voltage Drop Per Function:
400.0 millivolts ac 2nd radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts ac 1st radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 3rd radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 4th radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 3rd radio interference 3rd function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
2 threaded hole
Functional Terminal Type And Quantity:
4 tab, solder lug output 2nd function
Functional Terminal Type And Quantity:
5 tab, solder lug input 1st function
Functional Terminal Type And Quantity:
7 turret ground 3rd function
Operating Voltage Rating And Type Per Function:
26.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Thread Size:
0.138 inches
Maximum Dielectric Withstanding Dc Voltage:
322.0 volts at sea level
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Filter,ac Power
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC